GDZRC-100U Transformer DC Winding Resistance Tester
Transformer DC winding resistance is a required test item for the factory test, installation, overhaul, change of tap switch, handover test and preventive test of power department.
-
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.
-
GDOT-80C Insulation Oil Breakdown Tester 80kV
There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation.
-
GDOT-100C Insulation Oil Breakdown Tester 100kV
GDOT-100C Insulation Oil Breakdown Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.
-
GDB-D Transformer Turn Ratio Tester
GDB-D Transformer turn ratio tester is designed for three phases transformer in power system and especially for Z type winding transformer and other transformers with relatively large no-load current.
-
GDB-H Handheld Automatic Transformer Turns Ratio Tester
It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers.
-
GDB-IV Three Phase Transformer Turns Ratio Tester
The internal power module in the tester generates the three-phase power or two-phase power, which is output to the high voltage side of the transformer. Then the high voltage and low voltage are sampled at the same time. Finally, the group, ratio, error, and phase difference are calculated.
-
GDZJ-10S Turn-to-turn Surge Tester
GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment.
-
GDPD-306M Portable Ultrasonic Partial Discharge Detector
GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection.
-
Partial Discharge Online Monitoring System of Generators
Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform.
-
Impulse Voltage Test System – High Voltage Test Instruments
GDCY series Impulse Voltage Generator can produce a wide range of voltage and energy to simulate waveform such as lightning impulse, lightning clipped wave, switching impulse and so on, enable to carry out various forms of impulse test for high voltage power equipment, cooperate with steepening device can carry out steep wave test on the insulator (insulator string).
-
GD6900 Capacitance and Dissipation Factor Tester
GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.